Filter Results By:
Products
Applications
Manufacturers
Earth Resistance
Evaluation of the conductance of earth grounding.
-
product
Earth Ground Clamp Meter
T2000
T2000 is a professional clamps specially developed to evaluate resistance of earth rods with no need to disconnect any part of the system (STAKELESS METHOD)
-
product
Multi-function Tester
MFT5010
It can be used to test insulation resistance, continuity, loop impedance and RCCB, earth resistance tester, five major test requirement in the electrical testing industry. Phase indicator. Can check a wide range of 3-Phase Power source from 110V to 600V
-
product
Earth Ground Tester
Weshine Electric Manufacturing Co., Ltd
UT520 series can perform precise 3-wire and simple 2-wire earth resistance measurement for power and electrical systems, lightning protection equipment, and ground system of all electrical equipment.
-
product
Electronic Power Testers
Axi'An Beicheng Electronics Co., LTD.
Electronic Power Testers by RuoShui; HART process calibrators, process calibrators, digital earth resistance tester, insulation resistance tester, SMD resistor, digital capacitance inductance meter, LCR meters, surface resistance meter, and more
-
product
Multifunction Electrical Installation Meter
AMPI-520
The AMPI-520 digital meter is designed to measure impedance in short-circuit loops without tripping the differential protection, it also measures the protection tare, earth resistance, continuity and phase sequence check.
-
product
Safety Analyzer
SA-2000
The BC Biomedical SA2000 Features: AAMI Load Earth / Ground Lead Resistance Earth/Ground Leakage Current Chassis Leakage True RMS Measurements 85 to 265 VAC Operation.
-
product
Installation Testers
Offers two models that verify the safety of electrical installations in residential, commercial and industrial applications. Has been developed to carry out the following safety measurements of electrical installations in accordance with EN 61557 and DIN VDE 0100: Insulation resistance, RCD tests, Low Ohm resistance, Earth ground resistance, Loop impedance, Phase sequence.
-
product
Single channel Motor Insulation Monitor
The SURETECH Motor Insulation Monitor measures insulation resistance to earth of electric motors when themotor stops. Motors running from mains (380 / 220V) and higher voltages up to 6.6kV can have their insulationcontinuously monitored.
-
product
Multifunction Installation Tester
COMBI519
COMBI519 carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type B, A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.
-
product
Multifunction Tester
COMBI521
COMBI521 carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type B, A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.
-
product
Multifunction Tester
EASYTEST
EASYTEST carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.
-
product
PAT Check Box
369A910
The only check box to provide comprehensive verification of 17th Edition and PAT test equipment. The Powercheck tests for full earth continuity, insulation, resistance, RCD trip time, RCD trip current, touch current and flash test verification.
-
product
Clamp Meters
Our clamp meters measure both high and low AC and DC currents as well as earth leakage and earth resistance. With variable jaw sizes, max current readings up to 2000A AC/DC and features including TRMS, data logging and temperature readings we have clamps suitable for a wide range of electrical applications.
-
product
Multifunction Installation Testers
Shanghai Beha Electronics Co., Ltd.
Loop impedance and prospective short circuit current measurement• Line impedance and prospective short circuit current measurement• Earth loop resistance in TT-systems• Rotary field test• RCD measurements (contact voltage, trip time, trip current - ramp method)• RCD analysis for test of all RCD parameters • Low Ohm and continuity measurement • Insulation measurement up to 1000V (suitable for 690 V industrial mains systems)• Earth resistance measurement with probes and clamp adapters• Voltage and frequency measurement • Current measurement with clamp adapters(optional)• Power and energy measurements• Harmonics measurement for voltage and current upto the 21st harmonics
-
product
Earth Ground Clamp
1630-2
The 1630-2 FC clamp measures earth ground loop resistances for multi-grounded systems using the dual-clamp jaw. This test technique eliminates the dangerous and time-consuming activity of disconnecting parallel grounds, as well as the process of finding suitable locations for auxiliary test stakes.
-
product
Ground Fault Protection Monitors
The Earth Fault Resistance Monitor (EFREM) and the Rotor Health Monitor (RHM) provide wireless rotor ground fault and temperature monitoring for generators and motors. The systems replace older slip ring contact ground fault detectors on any synchronous generator or motor.
-
product
Multifunctional testers
MI 3152 EurotestXC
MI 3152 EurotestXC is an instrument from the new generation of Metrel’s multifunctional measuring instruments. The already well known functions like complete installation safety testing according to IEC/EN 61557 and AUTO SEQUENCE testing of TN, TT and IT earthing systems are managed by a completely new user interface based on large colour touch screen display. A wide range of functions is included: from on-line voltage monitoring, phase sequence testing, varistor testing, earth resistance measurement, illuminance measurement and TRMS current measurement up to RCD tests, line and loop impedance tests, specific earth resistance measurements as well as ISFL measurements and the IMD tests.
-
product
Multifunction Meter for Electrical Installations
AMPI-530
Measurement of short-circuit loop ; Testing of differential, general and selective protections for differential current ; Measurement of insulation resistance ; Up to 10GΩ ; Voltages: 50 V, 100 V, 250 V, 500 V, 1000 V ; Measurement of earth resistance ; Bi-directional continuity test on PE cables, phase sequence ; Measurement and recording of voltage, frequency, alternating current, cosϕ, power, harmonics and THD
-
product
Test Setup For Air Conditioner
SCR ELEKTRONIKS have developed TESTING SET UP FOR SINGLE PHASE / THREE PHASE MOTOR for carrying out Performance Test, Earth Contact Resistance Test, High Voltage Test, Megger Test and Leakage Current Test. It consists of Voltmeters, Ammeters and Wattmeters for observing the values of different parameters. OK / NOT OK lamps are also provided to display the results of Earth Contact Resistance Test, HV test, Megger Test, Leakage Current Test. All tests are provided with tripping cut off concept.
-
product
Earth Ground Testers
Fluke''s family of earth ground testers have been built to address the entire spectrum of ground testing methods from the basic to the most advanced. Our testers have been designed to be accurate, safe and easy to use. We provide quick and precise resistance measurements through several test methods: 3- and 4-pole Fall-of-Potential testing, selective testing, stakeless testing and 2-pole testing. Detailed application information can be found at the Earth Ground Solution Center.
-
product
Earth/Ground Resistance Tester
DE-5030
Earth resistance range0~12 / 0~120 / 0~1200 Normal operation conditionsBattery voltagein range of "BATT.GOOD" Earth voltage measurementmax. AC 30V Output current3mA Response timewithin 1 sec. Insulation resistancemin. 100M / DC1000V between input terminals and case Withstand voltageAC3700V (50 / 60Hz) for 1 min. between input terminals and case Battery Check Battery1.5V x 4 Safety standardIEC 61010-1 CAT.III 300V IEC 61557, IEC61010-031
-
product
20Hz Injection Kit Monitoring System
Signals & Systems India Private Limited
The Display used to monitor the 20Hz and 50Hz current passing through NGT transformer. This could help to monitor the stator earth fault and could record the current every minute. The current shall be displayed in milliamps for both 20Hz and 50Hz. If an earth fault occurs in the generator star point, the 20 Hz voltage drives a current through the fault resistance. The current can be measured using clamp-on CT which would be clamped between load resistor and NGT. It gives an indication of the current values are lower or higher than the set threshold.
-
product
PAT and Installation Verification Unit
PowerCheck 1557
The PowerCheck 1557 is a comprehensive PAT and installation verification checkbox. It carries out ongoing performance checks to ensure accurate measurement between calibration intervals. Fully tests Earth Continuity, Insulation Resistance, RCD Trip Time, RCD Trip Current, Loop, PE Conductor Current, Touch Current and Flash tests.
-
product
Earthing Resistance Tester
JYD-10A
transformer neutral grounding resistor is the vital need in medium voltage AC distribution network that are also called by different names like Neutral Earthling Resistors. They are taken into use to limit the current that would flow through the neutral point of a transformer or generator in the event of an earth fault. They are also used for resistance grounding of connected generators and transformers.
-
product
Multifunction Instrument
COMBI521EV
COMBI521EV is the new HT instrument to perform verification and control of electric car charging stations (EVSE) safety according to IEC / EN 61851-1 and IEC / EN60364-7-722 standards. Being a combined verification instrument, COMBI521EV also carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type B, A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.
-
product
Multifunctional testers
MI 3100 SE EurotestEASI
MI 3100 SE EurotestEASI is a fast, accurate and easy to use multifunctional measuring instrument which performs a complete set of installation safety tests according to IEC/EN 61557. Besides, the MI 3100 SE EurotestEASI enables on-line voltage monitoring, phase sequence testing and earth resistance measurement. EurotestEASI is equipped with integrated characteristics of fuses and RCDs for PASS / FAIL evaluation of test results.
-
product
Socket Tester with RCD Tripping
Shanghai Beha Electronics Co., Ltd.
*Mains wiring polarity check.*ELCB/RCD testing.*Measuring ear for line current.*Measuring ear for leakage current.*Helps calculate insulation resistance.*Helps calculate power consumption.*Helps fault finding of standing earth fault.*Fused main adapter.*Appliance testing (with the ad of a clamp meter).
-
product
Miller 400A
44500
Rugged, lightweight case - safe to use on wet ground• Weatherproof, even with lid removed - IP67 rating for dust and water intrusion• Convenient case lid removal for ease of movement, with test leads attached, to new measurement locations• Resistance measurement range from 0.01Ω to 1.1MΩ • Resistance measurements are unaffected by any stray interference signals that may be present in the earth during readings, due to the use of narrow band-pass filters centered at 97Hz (the unit’s operating frequency)• Runs on a set of C-cell alkaline batteries...no need to periodically recharge the unit or to plug it into a power source
-
product
Contact Resistance Meter
CRM 200B+
CRM directly measures micro-ohm values at 200A DC under live EHV switchyard conditions quickly & accurately. It is specially designed to reliably measure micro-ohm contact resistances of Circuit Breakers, Isolators, Busbar joints, earth switch joints, welded joints etc., under the hostile electrostatic noise found in live EHV switchyards up-to 765 kV. SCOPE’s ability to make electronics work in such environment enables CRM to measure mili-volts signal in the presence of kilo-volts noise.
-
product
Multifunctional testers
MI 3102 BT EurotestXE
MI 3102 BT EurotestXE is a multifunctional measuring instrument which performs a complete set of installation safety tests according to IEC/EN 61557. It supports AUTO SEQUENCE® testing of the TN, TT and IT earthing systems. ISFL measurements and the IMD tests can be performed. Besides, the MI 3102 BT EurotestXE enables on-line voltage monitoring, phase sequence testing, earth resistance measurement, illuminance measurement and TRMS current measurement. EurotestXE is equipped with integrated characteristics of fuses and RCDs for PASS / FAIL evaluation of test results.